Brands we install
Weil-McLain is the boiler we install most, and the one we see most in NYC basements: cast-iron gas boilers that run for decades, steam boilers that fit the city's pre-war buildings, and the newer condensing and combi units. We stock the parts that fail and know the control sequences by heart.
GW Mechanical Corp installs and repairs Weil-McLain boilers across Brooklyn, Queens, Staten Island and Manhattan. Call 646-980-2411.
Weil-McLain models we install and service
CGa and CGi (gas, hot water)
The standard cast-iron hot water boiler in NYC houses. CGa is atmospheric-vent, CGi is induced-draft. Long-lived; faults are usually ignition, rollout or vent switches.
EG, EGH and PEG (gas, steam)
Cast-iron steam boilers sized for brownstones and small buildings. We pipe the header to the manual, which is what keeps them from surging.
ECO Tec and Ultra (condensing, hot water)
High-efficiency wall-hung and floor units, 95 percent AFUE, vented in PVC or polypropylene out a side wall. Need a condensate drain and neutralizer.
AquaBalance (combi)
Wall-hung condensing combi: heat and domestic hot water from one unit. Right for small homes and apartments with no room for a tank.
GV90+ (power vent, hot water)
For houses with no usable chimney. Direct-vent cast iron with a sealed combustion blower.
SGO, WGO and WTGO (oil)
Oil steam and hot water boilers, common on Staten Island. We service the burner and convert to gas when the time comes.
Common Weil-McLain problems and what they mean
| Symptom or display | Usual cause | Fix |
|---|---|---|
| CGa will not light; pilot out or igniter sparks with no flame | Thermocouple (standing pilot) or failed hot-surface igniter; blocked pilot orifice; gas valve | Part replacement from truck stock; gas valve tested first |
| Boiler fires, then shuts off within a minute | Dirty flame sensor; tripped rollout switch; blocked-vent switch on CGi/GV | Clean or replace the sensor; find why the rollout tripped (flue, combustion air) before resetting |
| Ultra or ECO Tec shows a lockout or ignition-failure message | Flame sensor, igniter, blocked condensate trap, snow or debris at the side-wall vent, gas pressure | Read the code history on the control, clear the cause, reset once; repeated lockouts are a service call |
| Steam boiler (EG/PEG) surging, banging, or water level bouncing in the sight glass | Dirty water, near-boiler piping not to the manual, failed main vents, clogged pigtail | Skim and flush, correct the header piping, replace vents, clean the pigtail |
| Low-water cutoff keeps shutting the boiler down | Sediment in a float-type cutoff; probe needs cleaning; feeder not keeping up | Flush or clean the cutoff; check the automatic feeder |
| Relief valve dripping on a hot water boiler | Waterlogged expansion tank, pressure-reducing fill valve passing, or system over-pressure | Test and replace the expansion tank (see Amtrol), check the fill valve |
| Water on the floor under the boiler | Leaking section seal, failed circulator flange gasket, or a cracked section on an old unit | Gasket or circulator repair if the sections are sound; replacement if a section is cracked |
| Boiler runs but some rooms stay cold | Circulator or zone valve failure, air in the loop | See Taco circulators and zone valves |
Weil-McLain Ultra, ECO Tec and AquaBalance lockout messages
| Display | Meaning | Usual cause | What to do |
|---|---|---|---|
| Ignition failure / Lockout | Burner did not light in the allowed tries | Gas supply, dirty flame sensor, igniter, blocked vent or condensate | One reset; if it returns, service call |
| Flame loss | Flame went out during a cycle | Low gas pressure, wind at vent, flame sensor | Service call; gas pressure measured under load |
| Blocked vent / Air pressure | Pressure switch or air proving fault | Snow or debris at the side-wall termination, long vent, fan | Clear the termination outside |
| Condensate / Blocked drain | Condensate not draining | Frozen or clogged line, full trap, spent neutralizer | Clear the trap and line |
| High limit / Overheat | Supply temperature too high | Low flow, failed circulator, air in the loop, scale | Check circulator and bleed; service |
| Low water pressure | System pressure below the minimum | Leak, failed fill valve, waterlogged expansion tank | Refill to 12 to 15 psi; find the leak; check the Amtrol tank |
| Sensor fault (supply, return, flue, outdoor) | A thermistor reads out of range | Failed sensor or wiring | Service call; sensors on the truck |
| Fan speed / Blower | Fan not reaching commanded speed | Blower motor, blocked vent | Service call |
Reset once. A boiler that locks out repeatedly should not be reset again and again; each attempt loads the chamber with gas. Call and tell us the message on the display.
A cracked heat exchanger or section on a boiler past 25 years means replacement, and we say so in writing. Otherwise most Weil-McLain faults are same-day repairs: igniters, flame sensors, rollout and vent switches, gas valves, low-water cutoffs, circulators and relief valves are on the truck.
Before you call about a Weil-McLain
- Note the model (CGa-4, EG-45, Ultra 155, etc.) from the jacket label
- Note any message on the display and how many times it has locked out
- Check the emergency switch and the breaker
- On steam, look at the sight glass: is there water in it?
- Do not reset a lockout more than once
- Call 646-980-2411; most repairs are done on the first visit
Weil-McLain service by borough
Installed, repaired and stocked in every neighborhood we serve.
Brooklyn
ZIP codes 11201–11256
- Williamsburg
- Greenpoint
- DUMBO
- Brooklyn Heights
- Cobble Hill
- Carroll Gardens
- Red Hook
- Park Slope
Queens
ZIP codes 11004–11697
- Astoria
- Long Island City
- Sunnyside
- Woodside
- Jackson Heights
- Elmhurst
- Corona
- Flushing
Staten Island
ZIP codes 10301–10314
- St. George
- Tompkinsville
- Stapleton
- New Brighton
- West Brighton
- Port Richmond
- Westerleigh
- Clifton
Manhattan
ZIP codes 10001–10282
- Financial District
- Battery Park City
- Tribeca
- SoHo
- Chinatown
- Lower East Side
- East Village
- Greenwich Village
Questions
Who repairs Weil-McLain boilers near me in NYC?
GW Mechanical Corp repairs and installs Weil-McLain boilers across Brooklyn, Queens, Staten Island and Manhattan, with common parts on the truck. Call 646-980-2411.
Which Weil-McLain boiler is right for a NYC rowhouse?
For one-pipe steam, an EG or PEG sized to the radiation. For hot water, a CGa if there is a good chimney, an ECO Tec or Ultra for efficiency and side-wall venting, or an AquaBalance combi when space is tight.
How long does a Weil-McLain boiler last?
Cast-iron CGa and EG boilers commonly run 25 to 35 years with annual service. Condensing units such as the Ultra and ECO Tec are typically 15 to 20 years.
Why does my Weil-McLain keep locking out?
Usually a dirty flame sensor, a venting problem, a blocked condensate trap on condensing models, or low gas pressure. Repeated lockouts should not be reset again and again; they need a service visit.
Do you install Weil-McLain boilers in apartment buildings?
Yes, from EGH steam boilers in small buildings to multiple-boiler plants, with DOB filing and the work scheduled to keep the building in heat.
Manufacturer: Weil-McLain official website for product literature, warranty registration and current model lists.
Related: Boiler repair · Boiler replacement · Maintenance plans
Other brands: Taco · Amtrol · Everbilt · Watts · Kohler · Moen · Delta · Kraus · Navien · Rinnai · Noritz · All brands
Weil-McLain boiler trouble?
Parts on the truck, in all four boroughs.