GW Mechanical Corp

Contact Us

Call 646-980-2411

Weil-McLain boilers: installation, repair and parts in NYC

Weil-McLain boilers: installation, repair and parts in NYC

Brands we install

Weil-McLain is the boiler we install most, and the one we see most in NYC basements: cast-iron gas boilers that run for decades, steam boilers that fit the city's pre-war buildings, and the newer condensing and combi units. We stock the parts that fail and know the control sequences by heart.

GW Mechanical Corp installs and repairs Weil-McLain boilers across Brooklyn, Queens, Staten Island and Manhattan. Call 646-980-2411.

Weil-McLain models we install and service

CGa and CGi (gas, hot water)

The standard cast-iron hot water boiler in NYC houses. CGa is atmospheric-vent, CGi is induced-draft. Long-lived; faults are usually ignition, rollout or vent switches.

EG, EGH and PEG (gas, steam)

Cast-iron steam boilers sized for brownstones and small buildings. We pipe the header to the manual, which is what keeps them from surging.

ECO Tec and Ultra (condensing, hot water)

High-efficiency wall-hung and floor units, 95 percent AFUE, vented in PVC or polypropylene out a side wall. Need a condensate drain and neutralizer.

AquaBalance (combi)

Wall-hung condensing combi: heat and domestic hot water from one unit. Right for small homes and apartments with no room for a tank.

GV90+ (power vent, hot water)

For houses with no usable chimney. Direct-vent cast iron with a sealed combustion blower.

SGO, WGO and WTGO (oil)

Oil steam and hot water boilers, common on Staten Island. We service the burner and convert to gas when the time comes.

Common Weil-McLain problems and what they mean

Symptom or displayUsual causeFix
CGa will not light; pilot out or igniter sparks with no flameThermocouple (standing pilot) or failed hot-surface igniter; blocked pilot orifice; gas valvePart replacement from truck stock; gas valve tested first
Boiler fires, then shuts off within a minuteDirty flame sensor; tripped rollout switch; blocked-vent switch on CGi/GVClean or replace the sensor; find why the rollout tripped (flue, combustion air) before resetting
Ultra or ECO Tec shows a lockout or ignition-failure messageFlame sensor, igniter, blocked condensate trap, snow or debris at the side-wall vent, gas pressureRead the code history on the control, clear the cause, reset once; repeated lockouts are a service call
Steam boiler (EG/PEG) surging, banging, or water level bouncing in the sight glassDirty water, near-boiler piping not to the manual, failed main vents, clogged pigtailSkim and flush, correct the header piping, replace vents, clean the pigtail
Low-water cutoff keeps shutting the boiler downSediment in a float-type cutoff; probe needs cleaning; feeder not keeping upFlush or clean the cutoff; check the automatic feeder
Relief valve dripping on a hot water boilerWaterlogged expansion tank, pressure-reducing fill valve passing, or system over-pressureTest and replace the expansion tank (see Amtrol), check the fill valve
Water on the floor under the boilerLeaking section seal, failed circulator flange gasket, or a cracked section on an old unitGasket or circulator repair if the sections are sound; replacement if a section is cracked
Boiler runs but some rooms stay coldCirculator or zone valve failure, air in the loopSee Taco circulators and zone valves

Weil-McLain Ultra, ECO Tec and AquaBalance lockout messages

DisplayMeaningUsual causeWhat to do
Ignition failure / LockoutBurner did not light in the allowed triesGas supply, dirty flame sensor, igniter, blocked vent or condensateOne reset; if it returns, service call
Flame lossFlame went out during a cycleLow gas pressure, wind at vent, flame sensorService call; gas pressure measured under load
Blocked vent / Air pressurePressure switch or air proving faultSnow or debris at the side-wall termination, long vent, fanClear the termination outside
Condensate / Blocked drainCondensate not drainingFrozen or clogged line, full trap, spent neutralizerClear the trap and line
High limit / OverheatSupply temperature too highLow flow, failed circulator, air in the loop, scaleCheck circulator and bleed; service
Low water pressureSystem pressure below the minimumLeak, failed fill valve, waterlogged expansion tankRefill to 12 to 15 psi; find the leak; check the Amtrol tank
Sensor fault (supply, return, flue, outdoor)A thermistor reads out of rangeFailed sensor or wiringService call; sensors on the truck
Fan speed / BlowerFan not reaching commanded speedBlower motor, blocked ventService call

Reset once. A boiler that locks out repeatedly should not be reset again and again; each attempt loads the chamber with gas. Call and tell us the message on the display.

A cracked heat exchanger or section on a boiler past 25 years means replacement, and we say so in writing. Otherwise most Weil-McLain faults are same-day repairs: igniters, flame sensors, rollout and vent switches, gas valves, low-water cutoffs, circulators and relief valves are on the truck.

Before you call about a Weil-McLain

  • Note the model (CGa-4, EG-45, Ultra 155, etc.) from the jacket label
  • Note any message on the display and how many times it has locked out
  • Check the emergency switch and the breaker
  • On steam, look at the sight glass: is there water in it?
  • Do not reset a lockout more than once
  • Call 646-980-2411; most repairs are done on the first visit

Weil-McLain service by borough

Installed, repaired and stocked in every neighborhood we serve.

Brooklyn

ZIP codes 11201–11256

  • Williamsburg
  • Greenpoint
  • DUMBO
  • Brooklyn Heights
  • Cobble Hill
  • Carroll Gardens
  • Red Hook
  • Park Slope

Queens

ZIP codes 11004–11697

  • Astoria
  • Long Island City
  • Sunnyside
  • Woodside
  • Jackson Heights
  • Elmhurst
  • Corona
  • Flushing

Staten Island

ZIP codes 10301–10314

  • St. George
  • Tompkinsville
  • Stapleton
  • New Brighton
  • West Brighton
  • Port Richmond
  • Westerleigh
  • Clifton

Manhattan

ZIP codes 10001–10282

  • Financial District
  • Battery Park City
  • Tribeca
  • SoHo
  • Chinatown
  • Lower East Side
  • East Village
  • Greenwich Village

Questions

Who repairs Weil-McLain boilers near me in NYC?

GW Mechanical Corp repairs and installs Weil-McLain boilers across Brooklyn, Queens, Staten Island and Manhattan, with common parts on the truck. Call 646-980-2411.

Which Weil-McLain boiler is right for a NYC rowhouse?

For one-pipe steam, an EG or PEG sized to the radiation. For hot water, a CGa if there is a good chimney, an ECO Tec or Ultra for efficiency and side-wall venting, or an AquaBalance combi when space is tight.

How long does a Weil-McLain boiler last?

Cast-iron CGa and EG boilers commonly run 25 to 35 years with annual service. Condensing units such as the Ultra and ECO Tec are typically 15 to 20 years.

Why does my Weil-McLain keep locking out?

Usually a dirty flame sensor, a venting problem, a blocked condensate trap on condensing models, or low gas pressure. Repeated lockouts should not be reset again and again; they need a service visit.

Do you install Weil-McLain boilers in apartment buildings?

Yes, from EGH steam boilers in small buildings to multiple-boiler plants, with DOB filing and the work scheduled to keep the building in heat.

Manufacturer: Weil-McLain official website for product literature, warranty registration and current model lists.

Related: Boiler repair · Boiler replacement · Maintenance plans

Other brands: Taco · Amtrol · Everbilt · Watts · Kohler · Moen · Delta · Kraus · Navien · Rinnai · Noritz · All brands

Weil-McLain boiler trouble?

Parts on the truck, in all four boroughs.