Brands we install
Watts makes the safety and control valves that sit between the city main and everything in your building: the backflow preventer DEP requires, the pressure-reducing valve that keeps 100 psi street pressure from wrecking your fixtures, the relief valves on the boiler and water heater, and the mixing valve that keeps the tap at 120°F. We stock them and we carry the rebuild kits.
GW Mechanical Corp installs, tests and rebuilds Watts backflow preventers, pressure-reducing valves and relief valves across the four boroughs. Call 646-980-2411.
Watts products we install and service
Backflow preventers: 009 and 909 RPZ, LF007 and 709 double check
DEP-required devices for commercial buildings, restaurants, boilers with direct feed and irrigation. Installed, tested annually by a certified tester, rebuilt with Watts kits, reports filed.
Pressure-reducing valves: LF25AUB, LFN45B, LF223
Set the house pressure to 50 to 65 psi from whatever the street delivers. A failed PRV shows up as pressure that is too high, too low, or that creeps up overnight.
Relief valves: 3L and 374A boiler relief, 100XL and 40XL T&P
The valve that opens before a boiler or water heater does. Replaced on sight if it drips after testing.
Thermostatic mixing valves: LFMMV, LFUSG-B, 70A
Blend hot and cold at the water heater or at the fixture so a 140°F tank delivers 120°F at the tap. Code-required on many installs and the right fix for scalding complaints.
Boiler feed and fill valves: 1156F, B1156F, 911 backflow-feed combos
The automatic fill that keeps a hot water boiler at 12 to 15 psi. A passing fill valve is a common cause of a dripping boiler relief valve.
Water hammer arrestors, check valves, gauges, strainers and ball valves
The small parts that stop banging pipes, backflow into the heater, and leaks at a seized shutoff.
Common Watts valve problems
| Symptom | Likely Watts part | Fix |
|---|---|---|
| Backflow preventer dripping or spraying from the relief port | 009 or 909 RPZ: fouled first check or relief valve seat, often after street work stirred debris | Rebuild with a Watts repair kit, retest, file the report |
| Annual backflow test failed | Any assembly: worn checks, springs, seats | Rebuild on the spot and retest; replace if the body is pitted |
| Water pressure too high (over 80 psi), fixtures failing, relief valves dripping | PRV failed open or missing | Install or replace the LF25AUB, set to 55 to 65 psi, add an expansion tank if not present |
| Pressure too low or fades when a second fixture opens | PRV strainer clogged or diaphragm failed | Clean the strainer or replace the valve |
| Boiler relief valve drips | Fill valve passing, or expansion tank waterlogged | Test the tank first; replace the 1156F if it will not hold |
| Water too hot at the tap, or scalding complaints | Mixing valve failed or never installed | Install or replace the LFMMV, set and verify 120°F at the tap |
| Banging pipes when a washer or dishwasher valve closes | No water hammer arrestor | Install arrestors at the appliance supplies |
Watts parts are on the truck because they are what fails between the main and the fixtures. On a backflow call we bring the rebuild kit for the assembly size on file so the device passes the same visit.
Tell us
- The number on the valve body (009, 909, LF25AUB, 1156F)
- The pipe size (3/4, 1, 1-1/2, 2 inch)
- What it is doing: dripping, spraying, pressure high or low
- For backflow: the DEP notice date, if you have one
- Call 646-980-2411
Watts service by borough
Installed, repaired and stocked in every neighborhood we serve.
Brooklyn
ZIP codes 11201–11256
- Williamsburg
- Greenpoint
- DUMBO
- Brooklyn Heights
- Cobble Hill
- Carroll Gardens
- Red Hook
- Park Slope
Queens
ZIP codes 11004–11697
- Astoria
- Long Island City
- Sunnyside
- Woodside
- Jackson Heights
- Elmhurst
- Corona
- Flushing
Staten Island
ZIP codes 10301–10314
- St. George
- Tompkinsville
- Stapleton
- New Brighton
- West Brighton
- Port Richmond
- Westerleigh
- Clifton
Manhattan
ZIP codes 10001–10282
- Financial District
- Battery Park City
- Tribeca
- SoHo
- Chinatown
- Lower East Side
- East Village
- Greenwich Village
Questions
Who tests and repairs Watts backflow preventers near me?
GW Mechanical Corp tests, rebuilds and installs Watts backflow preventers across Brooklyn, Queens, Staten Island and Manhattan, with a certified tester and the report filed with DEP. Call 646-980-2411.
What does a Watts pressure-reducing valve do?
It lowers the street pressure to a safe house pressure, usually 55 to 65 psi. When it fails, fixtures and relief valves start failing. We replace it and set it with a gauge.
Why is my Watts 009 backflow preventer leaking?
The relief port discharges when the first check is fouled or the relief valve seat is worn, often after debris from street work. It is rebuilt with a Watts kit and retested.
Do you install mixing valves on water heaters?
Yes. A Watts thermostatic mixing valve lets the tank run hotter for capacity and Legionella control while delivering 120°F at the tap.
Manufacturer: Watts official website for product literature, warranty registration and current model lists.
Related: Backflow testing · Low water pressure · Hot water tank replacement
Other brands: Weil-McLain · Taco · Amtrol · Everbilt · Kohler · Moen · Delta · Kraus · Navien · Rinnai · Noritz · All brands
Backflow notice or pressure problem?
Watts valves and rebuild kits on the truck.