Brands we install
Noritz units are the third tankless brand we service regularly in NYC, especially the NRC and EZ condensing series and the commercial NC units in restaurants. The error codes follow the same logic as the other brands: ignition, venting, scale and sensors, with a few Noritz-specific maintenance codes that tell you the unit wants service.
GW Mechanical Corp installs and repairs Noritz tankless water heaters across the four boroughs. Call 646-980-2411.
Noritz models we install and service
NRC and NRCP series
Condensing residential tankless, 180,000 to 199,000 BTU; NRCP adds recirculation.
EZ series (EZ98, EZ111)
Designed as direct tank replacements with top connections; common in retrofits.
NR series non-condensing
Older installs with stainless venting.
NC commercial units and cascades
Restaurants, salons and buildings.
Annual service
Descaling flush, filters, condensate, combustion check; clears the 920 and 930 maintenance codes.
Noritz error codes: what they mean and what to do
| Code | Meaning | Usual cause | What to do |
|---|---|---|---|
| 11 | Ignition failure | Gas off or low pressure, air in gas line, igniter, flame rod | Check gas; one reset; call |
| 12 | Flame loss | Low gas pressure, undersized line, vent, dirty flame rod | Service call |
| 14 | Thermal fuse / overheat | Scale, restricted flow | Flush; service |
| 16 | Over temperature | Scale, low flow | Flush |
| 29 | Condensate neutralizer or drain blocked | Blocked or frozen condensate | Clear the line |
| 31 | Inlet thermistor | Sensor | Service call |
| 32 | Outlet thermistor | Sensor | Service call |
| 33 | Heat exchanger thermistor | Sensor or scale | Service call |
| 51 | Gas solenoid valve | Gas valve or wiring | Service call |
| 61 | Fan fault | Fan motor, blocked vent | Check terminations; fan |
| 66 | Bypass servo valve | Mixing valve fault | Service call |
| 71 | Gas valve drive circuit | Board or valve | Service call |
| 72 | False flame detection | Flame rod or board | Service call |
| 73 | DIP switch or setting error | Settings changed, board | Service call |
| 90 | Combustion abnormality | Vent blockage, gas pressure, dirty burner | Check terminations; combustion service |
| 99 | Combustion blocked, unit locked out | Severe vent or burner problem | Do not reset; service call |
| 920 | Neutralizer maintenance due | Neutralizer media consumed | Service the neutralizer |
| 930 | Scale or maintenance due | Scale building | Descaling flush |
Turn the unit off and on once. If the code returns, stop resetting and call; repeated ignition attempts on a fault are unsafe. Codes 920 and 930 are reminders rather than failures, and they are the unit asking for the yearly service that prevents the real codes. Code 99 means the unit has locked out for a combustion problem and should not be reset until it is checked.
Before you call about a Noritz
- Note the code on the controller
- Check the gas valve and other gas appliances
- Look at the vent terminations outside
- Note the model from the label
- Reset once, except code 99
- Call 646-980-2411
Noritz service by borough
Installed, repaired and stocked in every neighborhood we serve.
Brooklyn
ZIP codes 11201–11256
- Williamsburg
- Greenpoint
- DUMBO
- Brooklyn Heights
- Cobble Hill
- Carroll Gardens
- Red Hook
- Park Slope
Queens
ZIP codes 11004–11697
- Astoria
- Long Island City
- Sunnyside
- Woodside
- Jackson Heights
- Elmhurst
- Corona
- Flushing
Staten Island
ZIP codes 10301–10314
- St. George
- Tompkinsville
- Stapleton
- New Brighton
- West Brighton
- Port Richmond
- Westerleigh
- Clifton
Manhattan
ZIP codes 10001–10282
- Financial District
- Battery Park City
- Tribeca
- SoHo
- Chinatown
- Lower East Side
- East Village
- Greenwich Village
Questions
Who repairs Noritz tankless water heaters near me in NYC?
GW Mechanical Corp installs and repairs Noritz units across Brooklyn, Queens, Staten Island and Manhattan. Call 646-980-2411.
What does Noritz code 11 mean?
Ignition failure. Usually the gas supply or pressure, air in the gas line after work, or a dirty igniter or flame rod. Check the gas valve, reset once, and call if it returns.
What does Noritz code 90 or 99 mean?
A combustion abnormality, usually from a blocked vent, low gas pressure or a dirty burner. Code 99 is a lockout and should not be reset until the unit is serviced.
What do Noritz codes 920 and 930 mean?
Maintenance reminders: 920 for the condensate neutralizer, 930 for scale. The unit keeps running but needs its yearly service.
Manufacturer: Noritz official website for product literature, warranty registration and current model lists.
Related: Tankless water heaters · Restaurant plumbing · Maintenance plans
Other brands: Weil-McLain · Taco · Amtrol · Everbilt · Watts · Kohler · Moen · Delta · Kraus · Navien · Rinnai · All brands
Noritz showing a code?
Tell us the number. Parts on the truck.