Brands we install
Navien is the tankless and combi brand we install most, and the one whose error codes bring the most calls. The NPE tankless series and the NCB combi boilers are reliable when they are installed to spec and flushed yearly, and most codes point to one of a handful of causes: venting, condensate, gas supply, scale or a sensor. The table below is what we check, in the order we check it.
GW Mechanical Corp installs, services and repairs Navien tankless water heaters and combi boilers across the four boroughs, with common Navien parts on the truck. Call 646-980-2411.
Navien models we install and service
NPE-A2 series tankless (NPE-180A2, 210A2, 240A2)
Condensing tankless with built-in recirculation pump and buffer tank. The standard whole-house unit we install in NYC houses and apartments.
NPE-S2 series
Same heat exchanger without the recirculation hardware; for smaller homes and retrofits.
NCB-H and NCB-E combi boilers
Heat and domestic hot water from one wall-hung unit. Right for small houses and apartments replacing a boiler and a water heater at once.
NFC and NHB heating boilers
Condensing heating-only boilers, often paired with an indirect tank.
NaviLink Wi-Fi and cascade systems
Remote monitoring, and multi-unit cascades for restaurants, gyms and buildings.
Annual service
Descaling flush through the isolation valves, inlet filter and air filter cleaned, condensate trap cleared, combustion checked. The single thing that keeps a Navien running 20 years.
Navien error codes: what they mean and what to do
| Code | Meaning | Usual cause | What to do |
|---|---|---|---|
| E001 | Boiler overheated | Scale in the heat exchanger, low flow, failed thermistor | Turn off, let cool, call; usually a descaling flush |
| E003 | Ignition failure | Gas supply off or low pressure, air in the gas line after work, blocked vent, dirty igniter or flame rod | Check the gas valve is open; one reset; if it returns, service call |
| E004 | False flame detection | Flame rod or control fault | Service call |
| E012 | Flame loss during operation | Low gas pressure, undersized gas line, wind at the vent, dirty flame rod | Common on units on a small gas line; we measure pressure under load |
| E016 | Overheat, heat exchanger | Scale, blocked exchanger, low flow | Descaling flush; check inlet filter |
| E027 | Air pressure sensor | Blocked intake or exhaust, pressure sensor fault | Check the terminations outside for snow, leaves or nests |
| E030 | Exhaust temperature high | Scale, dirty exchanger, fan issue | Service call |
| E035 | Gas pressure sensor | Low inlet gas pressure | Gas supply or line sizing problem |
| E038 | Condensate trap blocked | Condensate line frozen or clogged, trap full | Clear the trap and line; common in winter |
| E046 | Abnormal operation, water flow | Flow sensor, scale, inlet filter | Clean filter, flush |
| E047 | Exhaust thermistor | Sensor fault or overheating exhaust | Service call |
| E109 | Fan speed abnormal | Blocked vent, fan motor, long vent run | Check terminations; fan replacement if needed |
| E110 | Exhaust blockage or air pressure | Snow, ice or debris at the vent, excessive vent length, bird nest | Clear the termination; the most common winter code |
| E302 | Low water pressure (NCB) | System pressure below about 0.5 bar, leak, failed expansion tank | Refill to 12 to 15 psi; find the leak |
| E407 | Outlet thermistor | Sensor fault | Service call |
| E421 | Cold water inlet thermistor | Sensor fault | Service call |
| E438 | Low water level, buffer tank (NPE-A2) | Air in the recirculation loop, buffer tank sensor | Bleed the loop; sensor if persistent |
| E441 | Flow sensor | Scale or failed flow sensor | Flush or replace |
| E515 | Abnormal PCB operation | Power supply, surge, control board | Power cycle once; board replacement if it returns |
| E593 | Front panel fault | Panel or wiring | Service call |
| E615 | Input error or PCB communication | Wiring, DIP switch setting, board | Service call |
| E740 | Outdoor temperature sensor (NCB) | Sensor or wiring | Service call |
Turn the unit off and on once. If the code returns, stop resetting and call; repeated ignition attempts on a fault are unsafe. Many codes come down to the same three things: the vent outside (E027, E109, E110), the condensate (E038) and scale (E001, E016, E046, E441). A yearly flush and a clear termination prevent most of them. We carry Navien flame rods, igniters, flow sensors, thermistors, fans and gaskets, so a diagnosed fault is usually fixed on the first visit.
Before you call about a Navien
- Read the code on the front panel and how many times it has appeared
- Check the gas valve is open and other gas appliances work
- Look at the vent terminations outside for snow, ice or debris
- Note the model (NPE-240A2, NCB-240E) from the label
- Reset once; do not keep resetting
- Call 646-980-2411
Navien service by borough
Installed, repaired and stocked in every neighborhood we serve.
Brooklyn
ZIP codes 11201–11256
- Williamsburg
- Greenpoint
- DUMBO
- Brooklyn Heights
- Cobble Hill
- Carroll Gardens
- Red Hook
- Park Slope
Queens
ZIP codes 11004–11697
- Astoria
- Long Island City
- Sunnyside
- Woodside
- Jackson Heights
- Elmhurst
- Corona
- Flushing
Staten Island
ZIP codes 10301–10314
- St. George
- Tompkinsville
- Stapleton
- New Brighton
- West Brighton
- Port Richmond
- Westerleigh
- Clifton
Manhattan
ZIP codes 10001–10282
- Financial District
- Battery Park City
- Tribeca
- SoHo
- Chinatown
- Lower East Side
- East Village
- Greenwich Village
Questions
Who repairs Navien water heaters near me in NYC?
GW Mechanical Corp installs, services and repairs Navien tankless and combi units across Brooklyn, Queens, Staten Island and Manhattan, with common Navien parts on the truck. Call 646-980-2411.
What does Navien error code E003 mean?
Ignition failure: the unit tried to light and could not. Usually gas supply or pressure, a blocked vent, or a dirty igniter or flame rod. Check the gas valve, reset once, and call if it returns.
What does Navien E110 mean?
Exhaust blockage or abnormal air pressure. In NYC winters it is usually snow or ice at the side-wall termination, or debris in the intake. Clear the termination; if the code stays, the fan or pressure sensor is checked.
How often should a Navien be flushed?
Once a year, with a descaling solution through the isolation valves, plus the inlet filter and air filter cleaned. NYC water is relatively soft, but a yearly flush is what prevents the overheat and flow codes.
Do you install Navien combi boilers in NYC apartments?
Yes, where there is a vent route and adequate gas; the NCB replaces a boiler and a water heater with one wall-hung unit. We coordinate co-op paperwork and DOB gas filing.
Manufacturer: Navien official website for product literature, warranty registration and current model lists.
Related: Tankless water heaters · Boiler replacement · Maintenance plans
Other brands: Weil-McLain · Taco · Amtrol · Everbilt · Watts · Kohler · Moen · Delta · Kraus · Rinnai · Noritz · All brands
Navien showing a code?
Tell us the code. Parts on the truck.