By GW Mechanical Corp. Published November 4, 2026. About a 3 minute read.
In short
A restaurant needs hot water sized to the dish machine, the three-compartment sink and the hand sinks running together at peak, at the temperatures the health code requires (typically 110°F minimum at hand sinks and 120°F or higher for warewashing, with a booster to 180°F for high-temperature dish machines). Commercial storage tanks or tankless cascades with recirculation are the usual solutions; redundancy keeps the kitchen open when one unit fails.
A restaurant with no hot water closes, by rule and by necessity. The hot water system has to be sized to the kitchen at its busiest minute, not to the average, and it has to keep working when one part fails. This is how we size and build it.
What the kitchen needs
- Hand sinks: warm water, commonly at least 100 to 110°F, available at all times.
- Warewashing: hot water to the three-compartment sink and the dish machine; low-temperature chemical-sanitizing machines run around 120°F, high-temperature machines need a 180°F final rinse, supplied by a booster heater at the machine.
- Prep sinks, mop sinks, bar: all drawing at once at the end of service.
Health code temperature requirements are set by the NYC Health Code and the dish machine manufacturer; we size to the stricter of the two.
Sizing
We total the fixtures and the dish machine's rated hot water consumption per hour, look at the peak hour, and size storage and recovery to it with a margin. Undersizing shows up as a dish machine waiting to fill at 9 p.m. on Saturday.
The options
| Commercial storage tank | Tankless cascade | |
|---|---|---|
| Fit | Kitchens with space in the basement or back of house | Tight spaces; wall-hung in a mechanical closet |
| Peak | Storage carries the surge | Continuous flow at the cascade's rating |
| Redundancy | Add a second tank | Built in: one unit down, others carry |
| Maintenance | Flush, anode, relief valve | Annual descaling per unit |
| Booster | Separate booster at a high-temp machine | Same |
What else we install with it
Recirculation so hand sinks are hot immediately, mixing valves so hand sinks cannot scald, a backflow device on the main (DEP-required, tested annually), and the grease interceptor and drain work that goes with every kitchen. Installed and serviced outside service hours. Call 646-980-2411.
Questions
What size water heater does a restaurant need?
Sized to the dish machine's hourly hot water use plus every sink running at peak, with recovery to match. We calculate it from the equipment list.
Does a restaurant need a booster heater?
High-temperature dish machines need a 180°F final rinse, supplied by a booster at the machine. Low-temperature chemical machines do not.
Tank or tankless for a restaurant?
Storage tanks where there is space; tankless cascades where there is not, with built-in redundancy. Both with recirculation.
More on water heaters: 40 vs 50 gallon · 50 vs 75 · how long a tank lasts · expansion tank code · venting · permits · warranties · same-day replacement, hour by hour · leaking from the bottom · no hot water
Related: Restaurant plumbing · Building hot water · Backflow testing