In short
An atmospheric water heater vents up a chimney by natural draft and is the simplest and least expensive. A power vent uses a fan to push exhaust through plastic pipe out a side wall, for homes with no usable chimney or a flue that no longer drafts after a high-efficiency boiler stopped using it. Power vent costs more, needs an outlet, and makes a fan noise, but it is the right answer when the chimney is not.
Most NYC water heaters are atmospheric: a draft hood, a metal flue, a chimney. That stops working when the chimney is gone, unlined, or orphaned, and that is when power vent comes in.
Side by side
| Atmospheric vent | Power vent | |
|---|---|---|
| How it vents | Natural draft up a chimney or metal flue | Fan pushes exhaust through PVC out a side wall or roof |
| Needs | A sound, lined, correctly sized chimney | An outlet and a vent route to outside within distance limits |
| Cost | Lowest | Higher unit cost plus venting |
| Noise | Silent | Fan runs while heating |
| Power outage | Keeps working (standing pilot) | Stops |
| Backdraft risk | Yes, in tight basements or with a bad chimney | No; sealed fan-driven exhaust |
The orphaned flue problem
This is the NYC-specific reason power vent comes up. A house replaces its old boiler with a condensing unit that vents out a side wall. The chimney, which used to carry both the boiler and the water heater, now carries only the water heater. It is oversized for that small load, the flue gases cool before they reach the top, draft is poor, and exhaust spills into the basement. The fixes are a correctly sized chimney liner, or a power-vent water heater that does not use the chimney at all.
When each is right
- Atmospheric: the chimney is sound and sized for the heater (or lined to fit), and the basement has combustion air.
- Power vent: no chimney, an unlined or failing chimney, an orphaned flue, or a heater being relocated away from the chimney.
- Direct vent: a sealed unit that draws combustion air from outside through a second pipe; for very tight houses.
We check draft with the burner running on every atmospheric replacement, and tell you if the chimney will carry the new heater or not. Power-vent units are usually same or next day. Call 646-980-2411.
Questions
Do I need a power vent water heater?
Only if there is no usable chimney: none, unlined, failing, or orphaned after a boiler upgrade. If the chimney is sound, atmospheric is simpler and cheaper.
Why does my water heater backdraft after the new boiler was installed?
The chimney is now oversized for the water heater alone and drafts poorly. A sized liner or a power-vent heater fixes it.
Is a power vent water heater noisy?
There is a fan sound while it heats, similar to a bathroom exhaust fan. It is not loud, but it is not silent.