GW Mechanical Corp

Contact Us

Call 646-980-2411

No heat tonight: what to check, what not to do, and how to stay safe while the plumber is on the way

No heat tonight: what to check, what not to do, and how to stay safe while the plumber is on the way

By GW Mechanical Corp. Published November 2, 2026. About a 4 minute read.

In short

If the heat is out tonight: check the thermostat batteries and setting, the boiler emergency switch and breaker, the gas valve, and on a steam boiler the water level in the sight glass. Reset a locked-out boiler once, never repeatedly. Do not use an oven or grill for heat. Call 646-980-2411; GW Mechanical Corp dispatches. Tenants: no heat in heat season is an HPD violation; call 311 if the landlord does not act.

The heat went out, it is dark, and it is cold. Half of the no-heat calls we take at night turn out to be something the owner could have fixed in five minutes, and the other half need a plumber. Here is how to tell which you have, what to do in the meantime, and the one thing you must not do.

Five checks, in order (about ten minutes)

  • Thermostat. Is the display on? Dim or blank means dead batteries, the most common no-heat cause there is. Replace them. Is it set to Heat and above room temperature? Raise it five degrees and listen for the boiler.
  • Emergency switch. The red-plate light switch at the top of the basement stairs or by the boiler room door. Someone turns it off thinking it is a light. Make sure it is on.
  • Breaker. Find the boiler's breaker in the panel. If it is tripped, reset it once. If it trips again, stop; something is shorted.
  • Gas. Is the gas valve on the boiler open (handle in line with the pipe)? Do the stove burners light? If no gas anywhere, call Con Edison; it is a supply issue.
  • Steam boilers: water level. Look at the sight glass. If it is empty, the low-water cutoff has shut the boiler down to protect it. Do not add water to a hot, empty boiler; let it cool and call us. If the automatic feeder has failed, the boiler will not run until it is fixed.

One reset, then stop

If the boiler has a reset button or a lockout message, press it once. If it lights and stays lit, watch it for a few minutes. If it locks out again, do not keep resetting it. Each attempt loads the combustion chamber with gas, and repeated resets are how boilers get damaged and basements get dangerous. Two lockouts means a plumber.

What never to do for heat

  • Do not use the oven or stove to heat the home. Carbon monoxide builds fast and people die of this every winter in NYC.
  • Do not bring a grill, camp stove or generator indoors. Same reason.
  • Do not run a space heater on an extension cord or power strip, or near bedding and curtains. One heater per outlet, on the floor, three feet from anything.
  • Do not thaw frozen pipes with an open flame.

Staying warm safely until we arrive

  • Close off unused rooms and gather in one.
  • Layers, blankets, hats; body heat matters more than you think.
  • Let a faucet on an exterior wall drip if it is below 20°F outside, so the pipes do not freeze while the heat is off.
  • Open the cabinet doors under sinks on exterior walls.
  • If anyone in the home is elderly, an infant, or medically fragile and the house is getting cold, say so when you call; those calls go first.

If you rent

NYC heat season runs October 1 to May 31. Your landlord must keep the apartment at 68°F from 6am to 10pm when it is below 55°F outside and 62°F overnight. No heat is an HPD Class C violation. Call the landlord or super first and write down the time; if nobody responds, call 311 and file. Our heat season guide has the details.

If you own the building

Call us before the tenants call 311. We dispatch, prioritize building-wide outages, and give you the written record of the call time, arrival and repair that shows you acted promptly. Members of our maintenance plan are at the front of the line.

Call now

646-980-2411. A dispatcher answers, tells you what to check while the truck is moving, and gives you an arrival window. Brooklyn, Queens, Staten Island and Manhattan, every night of the year. Nearly every no-heat repair is finished on the first visit because the parts that fail at night, igniters, flame sensors, thermocouples, circulators, low-water cutoffs, are on the truck.

Questions

My heat went out at night. Who do I call in NYC?

GW Mechanical Corp dispatches across Brooklyn, Queens, Staten Island and Manhattan. Call 646-980-2411; check the thermostat batteries and the emergency switch while you wait.

Can I use my oven to heat my apartment?

No. It produces carbon monoxide and causes deaths every winter. Use blankets and layers, close off rooms, and call a plumber.

How many times can I reset my boiler?

Once. If it locks out again, stop and call; repeated resets are unsafe.

What should I do if my landlord will not fix the heat?

Call and document the time, then call 311. No heat in heat season is an HPD Class C violation.

Related: Boiler repair · Emergency plumber · Troubleshooting

Need a plumber now?

A dispatcher answers every call. Tell us what is wrong and where you are.